Shear Wave Bidimensional Elastography and UGAP, new technologies in Venezuela for the quantification of the degree of fibrosis and fat in the liver
Keywords:
elastography, shear wave, fatty liver, ultrasound, VenezuelaAbstract
Two-dimensional Supersonic Shear Wave Elastography (2D-SWE SSI) is a diagnostic technique that uses a stateof- the-art ultrasound scanner that can qualitatively (using a color scale) and quantitatively (in kilopascals or meters/ second) assess the stiffness of different tissues. This technology is combined with UGAP (Ultrasound Guided Attenuation Parameter), an index used to accurately assess the level of hepatic steatosis (fatty liver). This combination is a non-invasive tool that uses ultrasound to determine the attenuation of its waves as they pass through the liver. The fat accumulated in the liver influences the acoustic properties of liver tissue, producing greater attenuation of ultrasound waves the greater the problem. This technology measures and assesses the amount of fat present in the liver and is vitally important after treatment to measure (quantify) the patient’s progress or response to appropriate and timely treatment
Downloads
References
Caballería Rovira, L., Majeeda, I., Martínez Escudéa, A., Arteaga Pillasaguaa, I., Torán Monserrata, P. (2017). Esteatosis hepática: diagnóstico y seguimiento. FMC. 24(7): 378-89.
Ferrando, N., Morales, R., Nuñez, J., Poñachik, L., Scarone, G., Nieto, G., Perendones, M. (2023). Asociación de fibrosis hepática mediante elastografía por Shear Wave 2D y Score APRI. Rev Urug Med Interna. 8(3): 48-58.
Kuroda, H., Abe, T., Fujiwara, Y. et al. (2021). Diagnostic accuracy of ultrasound-guided attenuation parameter as a noninvasive test for steatosis in non-alcoholic fatty liver disease. J Med Ultrasonics. 48, 471–480. En: https://doi. org/10.1007/s10396-021-01123-0
Kyung Jeon, S., Min Lee, J., Joo, I., Hee Yoon, J. (2022). Assessment of the interplatform reproducibility of ultrasound attenuation examination in nonalcoholic fatty liver disease. Ultrasonography. 41(2): 355-364.
Prieto, JE., Garzón-Orjuela, N., Sánchez, S., Prieto, R., Ochoa, A., Soto, P., Eslava-Schmalbach, J. (2021). Elastografía en tiempo real (Supersonic), experiencia de un centro en Bogotá. Rev Colomb Gastroenterol. 36 (1): 58- 64. https://doi. org/10.22516/25007440.594
Servente, L., Avondet, F., Milans, S., Benech, N., Negreira, C., Brum, J. (2021). Elastografía por ultra sonido: revisión de aspectos técnicos y aplicaciones clínicas. Rev Imagenol. 24(2): 75-86.
Sonorad Guatemala. (2024) ¿Se puede medir el nivel de hígado graso con ultrasonido?; En: https:// sonoradguatemala.com/f/se-puede-medirel- nivel-de-h%C3%ADgado-graso-conultrasonido
Sonorad Guatemala. (2023). Elastografía Hepática Shear Wave y su Utilidad Diagnóstica. En: https://sonoradguatemala.com/estudioselastograf% C3%ADa/f/elastograf%C3%ADahep% C3%A1tica-shear-wave-y-su-utilidaddiagn% C3%B3stica
Wu, H., Zeng, Y., Chen, F., Peng, J., Chen, L. (2024). The Diagnostic Value of Ultrasound-guided Attenuation Parameter (UGAP) in metabolic fatty liver disease. Current Medical Imaging; 20. DOI: 10.2174/01157340562755042311260339 05, 2024, 20, e15734056275504
Zhao, Y., Jia, M., Zhang, C., Feng, X., Chen, J., Li, Q., Zhang, Y., Xu, W., Dong, Y., Jiang, Y., Liu, Y., Huang P. (2022). Reproducibility of ultrasound‑guided attenuation parameter (UGAP) to the noninvasive evaluation of hepatic steatosis. Scientific Reports, Nature Portafolio. 12(2876): 1-10. https://doi.org/10.1038/s41598-022- 06879-0
Yoo, J.-J.; Kim, S.G.; Kim, Y.S. The Diagnostic Accuracy of LOGIQ S8 and E9 Shear Wave Elastography for Staging Hepatic Fibrosis, in Comparison with Transient Elastography. Diagnostics. 2021; 11, 1817. https://doi.org/10.3390/ diagnostics11101817
Downloads
Published
Issue
Section
License

This work is licensed under a Creative Commons Attribution-ShareAlike 4.0 International License.